High Quality Good Performance 12inch Multi Parameter 5 Para Patient Monitor

Short Description:


  • Product name: H8 Multi Parameter Patient Monitor
  • Place of Origin: Guangdong, China
  • Brand Name: Hwatime
  • Model Number: H8
  • Warranty: 1 Year
  • Quality Certification: CE&ISO
  • Product Detail

    Product Tags

    High Quality Good Performance 12inch Multi Parameter 5 Para Patient Monitor,
    Multi Parameter Good Quality Cheap,

    Quick Details

    H8 Multi Parameter Patient Monitor (1)

    ECG Lead mode: 3-lead or 5-lead

    ECG Waveform: 4-lead, dual-channel 3-lead, single-channel

    NIBP Mode: Manual, Auto, STAT

    NIBP Measurement and alarm range: 0 ~ 100%

    NIBP Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified

    PR Measurement and alarm range: 30 ~ 250bpm

    PR Measurement accuracy: ±2bpm or ±2%, whichever is greater

    Application: Bedside/ICU/OR, Hospital/Clinic

    Supply Ability: 100 Unit/Per Day

    Packaging & Delivery:

    Packaging Details

    One main unit Patient monitor, one NIBP cuff and tube, one Spo2 sensor, one ECG Cable, one ground cable and Disposable ECG Electrodes.

    Product packaging size (length, width, height): 410MM*280MM*360MM

    GW: 5.5KG

    Delivery Port: Shenzhen, Guangdong

    Lead Time:

    Quantity(Units)

    1 - 50

    51 - 100

    >100

    Est. Time(days)

    15

    20

    To be negotiated

    Usage

    Portable Patient Monitor can be used to monitor multiple physiological parameters including ECG(3-lead or 5-lead), Respiration(RESP), Temperature(TEMP), Pulse Oxygen Saturation(SPO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure(IBP) and carbon dioxide(CO2). All the parameters can be applied for adult, pediatric and neonate patients. The monitoring information can be displaying, reviewing, storing and recording.

    Product Description

    Product name H8 Multi Parameter Patient Monitor
    ECG Lead mode: 3-lead or 5-lead
    Lead selection: I, II, III, aVR, aVL, aVF, V
    Waveform: 5-lead, dual-channel
    3-lead, single-channel
    Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
    Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s 2 RESPARATION Method Impedance between R-F(RA-LL)
    Differential Input Impedance: >2.5MΩ
    Measuring Impedance Range:0.3~5.0Ω
    Base line Impedance Range:0 – 2.5KΩ
    Bandwidth: 0.3 ~ 2.5 Hz
    NIBP Method Oscillometric
    Mode Manual, Auto, STAT
    Measuring Interval in AUTO Mode
    1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
    Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm
    Alarm Type: SYS, DIA, MEAN4.SpO2
    Measurement and alarm range: 0 ~ 100%
    Resolution: 1%
    Measurement accuracy: 70%~100%: ±2%;
    0%~69%: unspecified
    PR Measurement and alarm range: 30 ~ 250bpm
    Measurement accuracy: ±2bpm or ±2%, whichever is greater
    TEMP Channel: dual-channel
    Measurement and alarm range: 0 ~ 50℃
    Resolution: 0.1 ℃
    Label:ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range
    ART : 0 ~ 300mmHg
    PA: -6 ~ 120mmHg
    CVP/RAP/LAP/ICP : -10 ~ 40mmHg
    P1/P2: -10 ~ 300mmHg
    Press Sensor Sensitivity: 5uV/V/mmHg
    Impedance: 300-3000Ω
    Resolution: 1mmHg
    Accuracy: +-2% or +- 1mmHg, which great
    Actualization interval: about 1 Sec. 7.EtCO2
    Method: Side-stream or Mainstream
    Measuring Range: 0~150mmHg
    Resolution:
    0~69mmHg, 0mmHg
    70~150mmHg, 0.2mmHg
    Accuracy:
    0~40 mm Hg ±2mm Hg
    41~70 mm Hg ±5%
    71~100 mm Hg ±8%
    101~150 mm Hg ±10%
    Aw-RR Range: 2~150 rpm
    Aw-RR Accuracy: ±1BPM
    Apnoea Alarm: Yes
    RESPARATION Respiratory monitoring principle
    Respiration is measured by the thoracic impedance. When the patient is breathing, the volume of air changes in the lungs, resulting in impedance changes between the electrodes. Respiration rate (RR) is calculated from these impedance changes, and a respiration waveform appears on the patient monitor screen.
    Method Impedance between R-F(RA-LL)
    Differential Input Impedance:  >2.5MΩ
    Measuring Impedance Range:0.3~5.0Ω
    Base line Impedance Range:0 – 2.5KΩ
    Bandwidth: 0.3 ~ 2.5 Hz