Nā kikoʻī wikiwiki
ECG Lead mode: 3-lead a i ʻole 5-lead
ECG Waveform: 4-lead, dual-channel 3-lead, single-channel
ʻO ke ʻano NIBP: Manual, Auto, STAT
ʻO ke ana ʻana o ka NIBP a me ka pae hoʻāla: 0 ~ 100%
NIBP ana pololei: 70% ~ 100%: ± 2%; 0%~69%: hōʻike ʻole ʻia
ʻO ke ana ʻana o PR a me ka pae hoʻāla: 30 ~ 250bpm
Pono ana ana PR: ±2bpm a i ʻole ±2%, ʻoi aku ka nui
Noi: Bedside/ICU/OR, Halemai/Clinic
Hiki ke hoolako:100 Unit/Pākahi lā
Puke a me ka lawe ʻana:
ʻIkepili Packaging
Hoʻokahi ʻāpana nui ka nānā ʻana i ka maʻi, hoʻokahi pahu NIBP a me ka paipu, hoʻokahi mea ʻike Spo2, hoʻokahi Uila ECG, hoʻokahi kelepona honua a me nā ECG Electrodes Disposable.
ʻO ka nui hōʻailona huahana (lōʻihi, laula, kiʻekiʻe): 410MM * 280MM * 360MM
GW: 5.5KG
Ke awa hoʻouna: Shenzhen, Guangdong
Ka manawa o waena o ka hoʻomaka a i ka wā pau:
Ka nui(Uni) | 1-50 | 51-100 | >100 |
Ka hikina. Manawa(lā) | 15 | 20 | E kūkākūkā ʻia |
Hoʻohana
Hiki ke hoʻohana ʻia ka Portable Patient Monitor e nānā i nā ʻāpana physiological he nui me ECG (3-lead a i ʻole 5-lead), Respiration (RESP), Temperature (TEMP), Pulse Oxygen Saturation (SPO2), Pulse Rate (PR), Non-invasive Blood. ʻO ke koʻikoʻi (NIBP), ʻo ke Koko Invasive (IBP) a me ka carbon dioxide (CO2). Hiki ke hoʻohana ʻia nā ʻāpana āpau no nā maʻi makua, pediatric a me nā neonate. Hiki ke hōʻike, loiloi, mālama a me ka hoʻopaʻa ʻana i ka ʻike nānā.
Hōʻike huahana
Inoa mea kūʻai | H8 Multi Parameter Mā'i Mākaʻikaʻi |
ECG | Ke ala alakaʻi: 3-lead a i ʻole 5-lead |
Koho alakaʻi: I, II, III, aVR, aVL, aVF, V | |
Ka nalu: 5-lead, dual-channel | |
3-alakaʻi, hoʻokahi-kanal | |
Loaʻa: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV | |
ʻO ka māmā ʻimi ʻana: 12.5mm/s, 25 mm/s, 50 mm/s 2 RESPARATION Ke ʻano o ka pale ʻana ma waena o RF(RA-LL) | |
Hoʻokomo ʻokoʻa impedance: >2.5MΩ | |
Ana Impedance Range:0.3~5.0Ω | |
Laina Impedance pae kumu: 0 - 2.5KΩ | |
Ka laulā: 0.3 ~ 2.5 Hz | |
NIBP | ʻO ke ʻano oscillometric |
Manaʻo Manual, Auto, STAT | |
Ana i ka waena ma ke ʻano AUTO | |
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) | |
Ana Ana ma ke ano STAT 5 Min Pulse Rate Range 40 ~ 240 bpm | |
ʻAno Alarm: SYS, DIA, MEAN4.SpO2 | |
Ana a me ka laha hoala: 0 ~ 100% | |
Hoʻoholo: 1% | |
Ke ana pololei: 70% ~ 100%: ± 2%; | |
0%~69%: hōʻike ʻole ʻia | |
PR | ʻO ke ana a me ke ʻano hoʻāla: 30 ~ 250bpm |
Ke ana pololei: ±2bpm a i ʻole ±2%, ʻoi aku ka nui | |
TEMP | Kanal: lua-kanal |
Ke ana a me ka pumehana: 0 ~ 50 ℃ | |
Hoʻoholo: 0.1 ℃ | |
Lepili:ART, PA, CVP, RAP, LAP, ICP, P1, P2 | |
Ana a me ka laula hoala | |
ART: 0 ~ 300mmHg | |
PA: -6 ~ 120mmHg | |
CVP/RAP/LAP/ICP : -10 ~ 40mmHg | |
P1/P2: -10 ~ 300mmHg | |
E kaomi i ka ʻike ʻike: 5uV/V/mmHg | |
Impedance: 300-3000Ω | |
Hoʻoholo: 1mmHg | |
Pono: +-2% a i ʻole +- 1mmHg, ʻoi loa | |
ʻO ka manawa kūpono: ma kahi o 1 Sec. 7.EtCO2 | |
Ke ʻano: ʻaoʻao-stream a i ʻole Mainstream | |
Ana Ana: 0~150mmHg | |
Hoʻoholo: | |
0~69mmHg, 0mmHg | |
70~150mmHg, 0.2mmHg | |
pololei: | |
0~40 mm Hg ±2mm Hg | |
41~70 mm Hg ±5% | |
71~100 mm Hg ±8% | |
101~150 mm Hg ±10% | |
Aw-RR Laulā: 2~150 rpm | |
Aw-RR Pono: ±1BPM | |
Alarm Apnea: ʻAe | |
HOOLAHA | ʻO ke kumu hoʻomalu hanu |
Ana ʻia ka hanu ʻana e ka thoracic impedance. Ke hanu ka mea maʻi, hoʻololi ka nui o ka ea i loko o ka māmā, e hopena i ka hoʻololi impedance ma waena o nā electrodes. Hoʻohālikelike ʻia ka helu hanu (RR) mai kēia mau hoʻololi impedance, a ʻike ʻia kahi ʻano nalu hanu ma ka pale kiaʻi maʻi. | |
ʻO ke ʻano Impedance ma waena o RF(RA-LL) | |
Hoʻokomo ʻokoʻa impedance: >2.5MΩ | |
Ana Impedance Range:0.3~5.0Ω | |
Laina Impedance pae kumu: 0 - 2.5KΩ | |
Ka laulā: 0.3 ~ 2.5 Hz |